Connections¶
The selection of the state and type of the TOUCH output signal is done by connecting the appropriate wires at the end of the connection cable. For this purpose, the PCT-414 quick-connecting terminal is supplied as an accessory.

Wire marking¶
| Colour | Wire |
|---|---|
| GND – white | |
| VCC – brown | |
| TOUCH – yellow | |
| GND/CFG – blue | |
| CFG1 – pink | |
| CFG2 – gray | |
| CFG3 – green |
Configurations¶
Six combinations of output state (NO, NC) and output type (PUSH-PULL, PNP, NPN) are available. The probe leaves the factory wired as NO / PUSH-PULL, with none of the configuration wires connected.
NO / PUSH-PULL¶
Factory setting.

NO / PNP¶

NO / NPN¶

NC / PUSH-PULL¶

NC / PNP¶

NC / NPN¶

Note
The output stages behind these settings are shown under Wiring Diagrams.